Black Square Analog King Air Air Condition & Pressurization presets
All 21 Air Condition & Pressurization presets of the Black Square Analog King Air in MSFS.
Inputs — what you press (21)
- BS KA Aft Blower Toggle
(L:var_AftBlowerSwitch, bool) ! (>L:var_AftBlowerSwitch, bool) (L:var_AftBlowerSwitch, bool) (>A:CIRCUIT SWITCH ON:139, bool)by Andrew Wilson - BS KA Blower Vent Switch Auto
1 (>A:CIRCUIT SWITCH ON:140, bool) 2 (>L:var_forwardVentBlowerState, number)by Andrew Wilson - BS KA Blower Vent Switch Lo
0 (>A:CIRCUIT SWITCH ON:140, bool) 1 (>L:var_forwardVentBlowerState, number)by Andrew Wilson - BS KA Cabin Pressurization Climb Rate Decrease
(L:var_pressurizationClimbRate, number) 150 > if{ (L:var_pressurizationClimbRate, number) 50 - (>L:var_pressurizationClimbRate, number)by Andrew Wilson - BS KA Cabin Pressurization Climb Rate Increase
(L:var_pressurizationClimbRate, number) 2000 < if{ (L:var_pressurizationClimbRate, number) 50 + (>L:var_pressurizationClimbRate, number) }by Andrew Wilson - BS KA Cabin Temperature Mode Auto (off)
(L:var_environmentalMode, number) 0 > if{ (L:var_environmentalMode, number) 3 - (>L:var_environmentalMode, number) }by Andrew Wilson - BS KA Cabin Temperature Mode Auto (on)
(L:var_environmentalMode, number) 3 < if{ (L:var_environmentalMode, number) 3 + (>L:var_environmentalMode, number)by Andrew Wilson - BS KA Cabin Temperature Mode Man Heat (off)
(L:var_environmentalMode, number) 0 > if{ (L:var_environmentalMode, number) 1 - (>L:var_environmentalMode, number) }by Andrew Wilson - BS KA Cabin Temperature Mode Man Heat (on)
(L:var_environmentalMode, number) 3 < if{ (L:var_environmentalMode, number) 1 + (>L:var_environmentalMode, number) }by Andrew Wilson - BS KA Cabin Temperature Mode Off (off)
(L:var_environmentalMode, number) 0 > if{ (L:var_environmentalMode, number) 2 - (>L:var_environmentalMode, number) }by Andrew Wilson - BS KA Cabin Temperature Mode Off (on)
(L:var_environmentalMode, number) 3 < if{ (L:var_environmentalMode, number) 2 + (>L:var_environmentalMode, number) }by Andrew Wilson - BS KA Electrical Heating Toggle
(L:var_ElectricHeatSwitch, bool) ! (>L:var_ElectricHeatSwitch, bool) (L:var_ElectricHeatSwitch, bool) (>A:CIRCUIT SWITCH ON:138, bool)by Andrew Wilson - BS KA Left Bleed Environmental Off
(A:CIRCUIT ON:78, bool) if{ 1 1 (>K:2:ENGINE_BLEED_AIR_SOURCE_SET) 1 (>L:var_environmentalBleedDisabled_L, bool) } 1 (>L:var_bleedState_L, number)by Andrew Wilson - BS KA Left Bleed Off
(A:CIRCUIT ON:78, bool) if{ 0 1 (>K:2:ENGINE_BLEED_AIR_SOURCE_SET) 1 (>L:var_environmentalBleedDisabled_L, bool) } 2 (>L:var_bleedState_L, number)by Andrew Wilson - BS KA Left Bleed On
(A:CIRCUIT ON:78, bool) if{ 1 1 (>K:2:ENGINE_BLEED_AIR_SOURCE_SET) 0 (>L:var_environmentalBleedDisabled_L, bool) } 0 (>L:var_bleedState_L, number)by Andrew Wilson - BS KA Right Bleed Environmental Off
(A:CIRCUIT ON:79, bool) if{ 1 2 (>K:2:ENGINE_BLEED_AIR_SOURCE_SET) 1 (>L:var_environmentalBleedDisabled_R, bool) } 1 (>L:var_bleedState_R, number)by Andrew Wilson - BS KA Right Bleed Off
(A:CIRCUIT ON:79, bool) if{ 0 2 (>K:2:ENGINE_BLEED_AIR_SOURCE_SET) 1 (>L:var_environmentalBleedDisabled_R, bool) } 2 (>L:var_bleedState_R, number)by Andrew Wilson - BS KA Right Bleed On
(A:CIRCUIT ON:79, bool) if{ 1 2 (>K:2:ENGINE_BLEED_AIR_SOURCE_SET) 0 (>L:var_environmentalBleedDisabled_R, bool) } 0 (>L:var_bleedState_R, number)by Andrew Wilson - CABIN ALT (DEC)
1 (>K:PRESSURIZATION_PRESSURE_ALT_DEC)by Alejandro Gómez B. - CABIN ALT (INC)
1 (>K:PRESSURIZATION_PRESSURE_ALT_INC)by Alejandro Gómez B. - CABIN TEMP
@ 420 / 0 max 100 min (>L:var_cabinTempAutoSet, number)by Alejandro Gómez B.
Outputs — what lights up (0)
None yet
New to MobiFlight?
MobiFlight connects your switches, encoders and displays to the Black Square Analog King Air — every preset on this page is ready to use in it.
Download MobiFlight- Install MobiFlightand connect your board or device.
- Download the latest presetsExtras › HubHop › Download Latest Presets.
- Assign and flyPick a preset for each button, encoder or light.