Inputs — what you press (21)

  • BS KA Aft Blower Toggle(L:var_AftBlowerSwitch, bool) ! (>L:var_AftBlowerSwitch, bool) (L:var_AftBlowerSwitch, bool) (>A:CIRCUIT SWITCH ON:139, bool)by Andrew Wilson
  • BS KA Blower Vent Switch Auto1 (>A:CIRCUIT SWITCH ON:140, bool) 2 (>L:var_forwardVentBlowerState, number)by Andrew Wilson
  • BS KA Blower Vent Switch Lo0 (>A:CIRCUIT SWITCH ON:140, bool) 1 (>L:var_forwardVentBlowerState, number)by Andrew Wilson
  • BS KA Cabin Pressurization Climb Rate Decrease(L:var_pressurizationClimbRate, number) 150 > if{ (L:var_pressurizationClimbRate, number) 50 - (>L:var_pressurizationClimbRate, number)by Andrew Wilson
  • BS KA Cabin Pressurization Climb Rate Increase(L:var_pressurizationClimbRate, number) 2000 < if{ (L:var_pressurizationClimbRate, number) 50 + (>L:var_pressurizationClimbRate, number) }by Andrew Wilson
  • BS KA Cabin Temperature Mode Auto (off)(L:var_environmentalMode, number) 0 > if{ (L:var_environmentalMode, number) 3 - (>L:var_environmentalMode, number) }by Andrew Wilson
  • BS KA Cabin Temperature Mode Auto (on)(L:var_environmentalMode, number) 3 < if{ (L:var_environmentalMode, number) 3 + (>L:var_environmentalMode, number)by Andrew Wilson
  • BS KA Cabin Temperature Mode Man Heat (off)(L:var_environmentalMode, number) 0 > if{ (L:var_environmentalMode, number) 1 - (>L:var_environmentalMode, number) }by Andrew Wilson
  • BS KA Cabin Temperature Mode Man Heat (on)(L:var_environmentalMode, number) 3 < if{ (L:var_environmentalMode, number) 1 + (>L:var_environmentalMode, number) }by Andrew Wilson
  • BS KA Cabin Temperature Mode Off (off)(L:var_environmentalMode, number) 0 > if{ (L:var_environmentalMode, number) 2 - (>L:var_environmentalMode, number) }by Andrew Wilson
  • BS KA Cabin Temperature Mode Off (on)(L:var_environmentalMode, number) 3 < if{ (L:var_environmentalMode, number) 2 + (>L:var_environmentalMode, number) }by Andrew Wilson
  • BS KA Electrical Heating Toggle(L:var_ElectricHeatSwitch, bool) ! (>L:var_ElectricHeatSwitch, bool) (L:var_ElectricHeatSwitch, bool) (>A:CIRCUIT SWITCH ON:138, bool)by Andrew Wilson
  • BS KA Left Bleed Environmental Off(A:CIRCUIT ON:78, bool) if{ 1 1 (>K:2:ENGINE_BLEED_AIR_SOURCE_SET) 1 (>L:var_environmentalBleedDisabled_L, bool) } 1 (>L:var_bleedState_L, number)by Andrew Wilson
  • BS KA Left Bleed Off(A:CIRCUIT ON:78, bool) if{ 0 1 (>K:2:ENGINE_BLEED_AIR_SOURCE_SET) 1 (>L:var_environmentalBleedDisabled_L, bool) } 2 (>L:var_bleedState_L, number)by Andrew Wilson
  • BS KA Left Bleed On(A:CIRCUIT ON:78, bool) if{ 1 1 (>K:2:ENGINE_BLEED_AIR_SOURCE_SET) 0 (>L:var_environmentalBleedDisabled_L, bool) } 0 (>L:var_bleedState_L, number)by Andrew Wilson
  • BS KA Right Bleed Environmental Off(A:CIRCUIT ON:79, bool) if{ 1 2 (>K:2:ENGINE_BLEED_AIR_SOURCE_SET) 1 (>L:var_environmentalBleedDisabled_R, bool) } 1 (>L:var_bleedState_R, number)by Andrew Wilson
  • BS KA Right Bleed Off(A:CIRCUIT ON:79, bool) if{ 0 2 (>K:2:ENGINE_BLEED_AIR_SOURCE_SET) 1 (>L:var_environmentalBleedDisabled_R, bool) } 2 (>L:var_bleedState_R, number)by Andrew Wilson
  • BS KA Right Bleed On(A:CIRCUIT ON:79, bool) if{ 1 2 (>K:2:ENGINE_BLEED_AIR_SOURCE_SET) 0 (>L:var_environmentalBleedDisabled_R, bool) } 0 (>L:var_bleedState_R, number)by Andrew Wilson
  • CABIN ALT (DEC)1 (>K:PRESSURIZATION_PRESSURE_ALT_DEC) by Alejandro Gómez B.
  • CABIN ALT (INC)1 (>K:PRESSURIZATION_PRESSURE_ALT_INC) by Alejandro Gómez B.
  • CABIN TEMP@ 420 / 0 max 100 min (>L:var_cabinTempAutoSet, number)by Alejandro Gómez B.

Outputs — what lights up (0)

None yet

New to MobiFlight?

MobiFlight connects your switches, encoders and displays to the Black Square Analog King Air — every preset on this page is ready to use in it.

Download MobiFlight
  1. Install MobiFlightand connect your board or device.
  2. Download the latest presetsExtras › HubHop › Download Latest Presets.
  3. Assign and flyPick a preset for each button, encoder or light.