Black Square Analog King Air Electrical presets

All 42 Electrical presets of the Black Square Analog King Air in MSFS.

Inputs — what you press (42)

  • BS KA ACTUATORS STANDBY LEFT1 (>var_InterSepStandbyMode_L)by P-38L
  • BS KA AVIONIC MASTER OFF0 (>L:var_avionicsMasterSwitch, bool) 4 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:17, Bool) if{ 4 17 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 2 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:19, Bool) if{ 2 19 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 3 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:21, Bool) if{ 3 21 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) }by Run Wild Production
  • BS KA AVIONIC MASTER ON1 (>L:var_avionicsMasterSwitch, bool) 4 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:17, Bool) ! if{ 4 17 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 2 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:19, Bool) ! if{ 2 19 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 3 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:21, Bool) ! if{ 3 21 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) }by Run Wild Production
  • BS KA BATT BUS OFF0 (>L:var_batteryDisconnect)by P-38L
  • BS KA BATT BUS OFF0 (>L:var_batteryDisconnect)by P-38L
  • BS KA BATT BUS ON1 (>L:var_batteryDisconnect)by P-38L
  • BS KA BATTERY MASTER OFF0 (>L:var_batteryMasterSwitch)by Run Wild Production
  • BS KA BATTERY MASTER ON1 (>L:var_batteryMasterSwitch)by Run Wild Production
  • BS KA BUS SENSE RESET0 (>L:var_busFaultDetected, bool) 0 (>L:var_simulatedBusFaultDetected, bool)by Stefan Kelley
  • BS KA BUS SENSE TEST1 (>L:var_busFaultDetected, bool) 1 (>L:var_simulatedBusFaultDetected, bool) 1 (>L:var_masterCautionLatching, number)by Stefan Kelley
  • BS KA EXTERNAL POWER OFF0 (>L:ELECTRICAL_ExternalPower_1) 0 (>L:ELECTRICAL_ExternalPower_2) (>K:TOGGLE_EXTERNAL_POWER)by Run Wild Production
  • BS KA EXTERNAL POWER ON(>K:TOGGLE_EXTERNAL_POWER) 1 (>L:ELECTRICAL_ExternalPower_1) 1 (>L:ELECTRICAL_ExternalPower_2) by Run Wild Production
  • BS KA GEN TIES MAN CLOSE OFF0 (>L:var_busTieManOpen, bool) 1 (>O:switchstate)by Stefan Kelley
  • BS KA GEN TIES MAN CLOSE ON1 (>L:var_busTieManClose, bool) 0 (>L:var_busTieManOpen, bool) 0 (>O:switchstate)by Stefan Kelley
  • BS KA GEN TIES OPEN OFF0 (>L:var_busTieManOpen, bool) 1 (>O:switchstate)by Stefan Kelley
  • BS KA GEN TIES OPEN ON0 (>L:var_busTieManClose, bool) 1 (>L:var_busTieManOpen, bool) 2 (>O:switchstate)by Stefan Kelley
  • BS KA L ALT OFF0 (>L:var_genReset_L, bool) 2 (>L:var_genSwitchPos_L, number)by Run Wild Production
  • BS KA L ALT ON0 (>L:var_genReset_L, bool) 1 (>L:var_genSwitchPos_L, number)by Run Wild Production
  • BS KA L ALT RESET1 (>L:var_genReset_L, bool) 0 (>L:var_genSwitchPos_L, number)by Run Wild Production
  • BS KA LEFT AC INVERTER BUS TRANSFER OFF6 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:4, Bool) if{ 6 4 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 6 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:3, Bool) if{ 6 3 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 7 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:4, Bool) if{ 7 4 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 7 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:3, Bool) if{ 7 3 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) }by Stefan Kelley
  • BS KA LEFT AC INVERTER BUS TRANSFER ON6 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:3, Bool) ! if{ 6 3 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 7 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:3, Bool) ! if{ 7 3 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) }by Stefan Kelley
  • BS KA LEFT AC INVERTER OFF6 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:4, Bool) if{ 6 4 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 6 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:3, Bool) if{ 6 3 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 7 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:4, Bool) if{ 7 4 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 7 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:3, Bool) if{ 7 3 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) }by Stefan Kelley
  • BS KA LEFT AC INVERTER ON6 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:4, Bool) ! if{ 6 4 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 7 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:4, Bool) ! if{ 7 4 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) }by Stefan Kelley
  • BS KA R ALT OFF0 (>L:var_genReset_R, bool) 2 (>L:var_genSwitchPos_R, number)by Stefan Kelley
  • BS KA R ALT ON0 (>L:var_genReset_R, bool) 1 (>L:var_genSwitchPos_R, number)by Stefan Kelley
  • BS KA R ALT RESET1 (>L:var_genReset_R, bool) 0 (>L:var_genSwitchPos_R, number)by Stefan Kelley
  • BS KA RIGHT AC INVERTER ON8 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:3, Bool) ! if{ 8 3 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 9 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:3, Bool) ! if{ 9 3 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) }by Stefan Kelley
  • BS KA RIGHT AC INVERTER BUS TRANSFER OFF8 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:3, Bool) if{ 8 3 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 8 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:4, Bool) if{ 8 4 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 9 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:3, Bool) if{ 9 3 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 9 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:4, Bool) if{ 9 4 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) }by Stefan Kelley
  • BS KA RIGHT AC INVERTER BUS TRANSFER ON8 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:4, Bool) ! if{ 8 4 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 9 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:4, Bool) ! if{ 9 4 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) }by Stefan Kelley
  • BS KA RIGHT AC INVERTER OFF8 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:3, Bool) if{ 8 3 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 8 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:4, Bool) if{ 8 4 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 9 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:3, Bool) if{ 9 3 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) } 9 (>A:BUS LOOKUP INDEX, Number) (A:BUS CONNECTION ON:4, Bool) if{ 9 4 (>K:2:ELECTRICAL_BUS_TO_BUS_CONNECTION_TOGGLE) }by Stefan Kelley
  • L GEN OFF(>K:TOGGLE_ALTERNATOR1) 0 (>L:var_genReset_L, bool) 2 (>L:var_genSwitchPos_L, number) by Alejandro Gómez B.
  • L GEN ON0 (>L:var_genReset_L, bool) 1 (>L:var_genSwitchPos_L, number)by Alejandro Gómez B.
  • L GEN RESET1 (>L:var_genReset_L, bool) 0 (>L:var_genSwitchPos_L, number)by Alejandro Gómez B.
  • R GEN OFF(>K:TOGGLE_ALTERNATOR2) 0 (>L:var_genReset_R, bool) 2 (>L:var_genSwitchPos_R, number) by Alejandro Gómez B.
  • R GEN ON0 (>L:var_genReset_R, bool) 1 (>L:var_genSwitchPos_R, number)by Alejandro Gómez B.
  • R GEN RESET1 (>L:var_genReset_R, bool) 0 (>L:var_genSwitchPos_R, number)by Alejandro Gómez B.
  • VOLT METER BUS SELECT - BAT6 (>L:var_meterMode, number)by Alejandro Gómez B.
  • VOLT METER BUS SELECT - CTR1 (>L:var_meterMode, number)by Alejandro Gómez B.
  • VOLT METER BUS SELECT - EXT PWR0 (>L:var_meterMode, number)by Alejandro Gómez B.
  • VOLT METER BUS SELECT - L GEN2 (>L:var_meterMode, number)by Alejandro Gómez B.
  • VOLT METER BUS SELECT - R GEN3 (>L:var_meterMode, number)by Alejandro Gómez B.
  • VOLT METER BUS SELECT - TPL FED4 (>L:var_meterMode, number)by Alejandro Gómez B.

Outputs — what lights up (0)

None yet

New to MobiFlight?

MobiFlight connects your switches, encoders and displays to the Black Square Analog King Air — every preset on this page is ready to use in it.

Download MobiFlight
  1. Install MobiFlightand connect your board or device.
  2. Download the latest presetsExtras › HubHop › Download Latest Presets.
  3. Assign and flyPick a preset for each button, encoder or light.