Fly By Wire A320-Dev Fuel presets

All 25 Fuel presets of the Fly By Wire A320-Dev in MSFS.

Inputs — what you press (10)

  • A32NX OVHD FUEL CTK L XFR Button Press9 (>K:FUELSYSTEM_VALVE_TOGGLE)by Jaime Leon
  • A32NX OVHD FUEL CTK R XFR Button Press10 (>K:FUELSYSTEM_VALVE_TOGGLE)by Jaime Leon
  • A32NX OVHD FUEL LTK PUMP1 PRESS2 (>K:FUELSYSTEM_PUMP_TOGGLE)by Jaime Leon
  • A32NX OVHD FUEL LTK PUMP2 PRESS5 (>K:FUELSYSTEM_PUMP_TOGGLE)by Jaime Leon
  • A32NX OVHD FUEL MODE SEL PRESS(L:A32NX_OVHD_FUEL_MODESEL_MANUAL) ! s0 (>L:A32NX_OVHD_FUEL_MODESEL_MANUAL) 1 l0 + sp0 l0 4 (>K:2:FUELSYSTEM_JUNCTION_SET) l0 5 (>K:2:FUELSYSTEM_JUNCTION_SET) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_MODESEL_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_MODESEL_Pressed)by Jaime Leon
  • A32NX OVHD FUEL RTK PUMP1 PRESS3 (>K:FUELSYSTEM_PUMP_TOGGLE)by Jaime Leon
  • A32NX OVHD FUEL RTK PUMP2 PRESS6 (>K:FUELSYSTEM_PUMP_TOGGLE)by Jaime Leon
  • A32NX OVHD FUEL XFEED PRESS3 (>K:FUELSYSTEM_VALVE_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_XFEED_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_XFEED_Pressed) by Jaime Leon
  • A32NX OVHD HYD RAT MAN ON BUTTON PRESS1 (>L:A32NX_OVHD_HYD_RAT_MAN_ON_IS_PRESSED)by Jaime Leon
  • A32NX OVHD HYD RAT MAN ON BUTTON RELEASE0 (>L:A32NX_OVHD_HYD_RAT_MAN_ON_IS_PRESSED)by Jaime Leon

Outputs — what lights up (15)

  • A32NX OVHD FUEL CTK L XFR OFF Annunciator(A:FUELSYSTEM VALVE SWITCH:9, Enum) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or (L:A32NX_ELEC_AC_2_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * by Schaller
  • A32NX OVHD FUEL CTK R XFR OFF Annunciator(A:FUELSYSTEM VALVE SWITCH:10, Enum) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or (L:A32NX_ELEC_AC_2_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * by Schaller
  • A32NX OVHD FUEL L TK Pump 1 Off(A:FUELSYSTEM PUMP SWITCH:2, Enum) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Schaller
  • A32NX OVHD FUEL L TK Pump 2 Off(A:FUELSYSTEM PUMP SWITCH:5, Enum) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or (L:A32NX_ELEC_AC_2_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * by Schaller
  • A32NX OVHD FUEL MODE SEL FAULT ON(A:FUELSYSTEM TANK WEIGHT:1, pound) 550 > (A:FUELSYSTEM TANK WEIGHT:2, pound) 11000 < (A:FUELSYSTEM TANK WEIGHT:3, pound) 11000 < or and (L:A32NX_OVHD_INTLT_ANN) 0 == (L:A32NX_ELEC_DC_2_BUS_IS_POWERED, Bool) and or (L:A32NX_ELEC_AC_1_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, Number) 2 == if{ 0.1 } els{ 1 } *by Jaime Leon
  • A32NX OVHD FUEL MODE SEL MAN ON(L:A32NX_OVHD_FUEL_MODESEL_MANUAL) (L:A32NX_OVHD_INTLT_ANN) 0 == (L:A32NX_ELEC_DC_2_BUS_IS_POWERED, Bool) and or (L:A32NX_OVHD_INTLT_ANN, Number) 2 == if{ 0.1 } els{ 1 } * by Jaime Leon
  • A32NX OVHD FUEL R TK Pump 1 Off(A:FUELSYSTEM PUMP SWITCH:3, Enum) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * by Schaller
  • A32NX OVHD FUEL R TK Pump 2 Off(A:FUELSYSTEM PUMP SWITCH:6, Enum) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or (L:A32NX_ELEC_AC_2_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * by Schaller
  • A32NX OVHD FUEL XFEED ON(A:FUELSYSTEM VALVE SWITCH:3, bool)by Jaime Leon
  • L TK Pump 1 Fault(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Schaller
  • L TK Pump 2 Fault(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_2_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * 0 > (A:CIRCUIT GENERAL PANEL ON, Bool) andby Schaller
  • Pump 1 Fault(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_2_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Schaller
  • Pump 2 Fault(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_1_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Schaller
  • R TK Pump 1 Fault(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Schaller
  • R TK Pump 2 Fault(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_2_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Schaller

New to MobiFlight?

MobiFlight connects your switches, encoders and displays to the Fly By Wire A320-Dev — every preset on this page is ready to use in it.

Download MobiFlight
  1. Install MobiFlightand connect your board or device.
  2. Download the latest presetsExtras › HubHop › Download Latest Presets.
  3. Assign and flyPick a preset for each button, encoder or light.