Fly By Wire A380X Fuel presets
All 84 Fuel presets of the Fly By Wire A380X in MSFS.
Inputs — what you press (28)
- FBW A380X Crossfeed 1 Press
46 (>K:FUELSYSTEM_VALVE_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_XFEED_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_XFEED_Pressed)by Andrew Spink - FBW A380X Crossfeed 2 Press
47 (>K:FUELSYSTEM_VALVE_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_XFEED_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_XFEED_Pressed)by Andrew Spink - FBW A380X Crossfeed 3 Press
48 (>K:FUELSYSTEM_VALVE_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_XFEED_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_XFEED_Pressed)by Andrew Spink - FBW A380X Crossfeed 4 Press
49 (>K:FUELSYSTEM_VALVE_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_XFEED_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_XFEED_Pressed)by Andrew Spink - FBW A380X Feed TK 1 Main Fuel Pump Press
2 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK1_MAIN_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK1_MAIN_Pressed)by Andrew Spink - FBW A380X Feed TK 1 Stby Fuel Pump Press
3 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK1_STBY_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK1_STBY_Pressed)by Andrew Spink - FBW A380X Feed TK 2 Main Fuel Pump Press
64 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK2_MAIN_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK2_MAIN_Pressed)by Andrew Spink - FBW A380X Feed TK 2 Stby Fuel Pump Press
65 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK2_STBY_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK2_STBY_Pressed)by Andrew Spink - FBW A380X Feed TK 3 Main Fuel Pump Press
66 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK3_MAIN_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK3_MAIN_Pressed)by Andrew Spink - FBW A380X Feed TK 3 Stby Fuel Pump Press
67 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK3_STBY_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK3_STBY_Pressed)by Andrew Spink - FBW A380X Feed TK 4 Main Fuel Pump Press
68 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK4_MAIN_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK4_MAIN_Pressed)by Andrew Spink - FBW A380X Feed TK 4 Stby Fuel Pump Press
69 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK4_STBY_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_FEEDTK4_STBY_Pressed)by Andrew Spink - FBW A380X Inr Tk Xfr Press
(L:A380X_OVHD_FUEL_INRTK_XFR_PB_IS_AUTO, Bool) ! (>L:A380X_OVHD_FUEL_INRTK_XFR_PB_IS_AUTO, Bool)by Andrew Spink - FBW A380X L Inr Tk Aft Fuel Pump Press
74 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_LINRTK_AFT_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_LINRTK_AFT_Pressed)by Andrew Spink - FBW A380X L Inr Tk Fwd Fuel Pump Press
73 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_LINRTK_FWD_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_LINRTK_FWD_Pressed)by Andrew Spink - FBW A380X L Mid Tk Aft Fuel Pump Press
72 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_LMIDTK_AFT_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_LMIDTK_AFT_Pressed)by Andrew Spink - FBW A380X L Mid Tk Fwd Fuel Pump Press
71 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_LMIDTK_FWD_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_LMIDTK_FWD_Pressed)by Andrew Spink - FBW A380X L Outr Tk Pmp Fuel Pump Press
70 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_LOUTRTK_PMP_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_LOUTRTK_PMP_Pressed)by Andrew Spink - FBW A380X Mid Tk Xfr Press
(L:A380X_OVHD_FUEL_MIDTK_XFR_PB_IS_AUTO, Bool) ! (>L:A380X_OVHD_FUEL_MIDTK_XFR_PB_IS_AUTO, Bool)by Andrew Spink - FBW A380X Outr Tk Xfr Press
(L:A380X_OVHD_FUEL_OUTRTK_XFR_PB_IS_AUTO, Bool) ! (>L:A380X_OVHD_FUEL_OUTRTK_XFR_PB_IS_AUTO, Bool)by Andrew Spink - FBW A380X R Inr Tk Aft Fuel Pump Press
79 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_RINRTK_AFT_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_RINRTK_AFT_Pressed)by Andrew Spink - FBW A380X R Inr Tk Fwd Fuel Pump Press
78 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_RINRTK_FWD_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_RINRTK_FWD_Pressed)by Andrew Spink - FBW A380X R Mid Tk Aft Fuel Pump Press
77 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_RMIDTK_AFT_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_RMIDTK_AFT_Pressed)by Andrew Spink - FBW A380X R Mid Tk Fwd Fuel Pump Press
76 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_RMIDTK_FWD_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_RMIDTK_FWD_Pressed)by Andrew Spink - FBW A380X R Outr Tk Pmp Fuel Pump Press
75 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_ROUTRTK_PMP_Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_ROUTRTK_PMP_Pressed)by Andrew Spink - FBW A380X Trim Tk L Fuel Pump Press
80 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_TRIMTKL__Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_TRIMTKL__Pressed)by Andrew Spink - FBW A380X Trim Tk R Fuel Pump Press
81 1 (>K:2:ELECTRICAL_BUS_TO_CIRCUIT_CONNECTION_TOGGLE) (L:XMLVAR_Momentary_PUSH_OVHD_FUEL_TRIMTKR__Pressed) ! (>L:XMLVAR_Momentary_PUSH_OVHD_FUEL_TRIMTKR__Pressed)by Andrew Spink - FBW A380X Trim Tk Xfr Press
(L:A380X_OVHD_FUEL_TRIMTK_XFR_PB_IS_AUTO, Bool) ! (>L:A380X_OVHD_FUEL_TRIMTK_XFR_PB_IS_AUTO, Bool)by Andrew Spink
Outputs — what lights up (56)
- FBW A380X Crossfeed 1 Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Crossfeed 1 On Annunciator
(A:FUELSYSTEM VALVE SWITCH:46, Bool) (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Crossfeed 2 Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Crossfeed 2 On Annunciator
(A:FUELSYSTEM VALVE SWITCH:47, Bool) (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Crossfeed 3 Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Crossfeed 3 On Annunciator
(A:FUELSYSTEM VALVE SWITCH:48, Bool) (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Crossfeed 4 Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Crossfeed 4 On Annunciator
(A:FUELSYSTEM VALVE SWITCH:49, Bool) (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 1 Main Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 1 Main Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:2, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 1 Stby Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 1 Stby Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:3, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 2 Main Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 2 Main Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:64, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 2 Stby Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 2 Stby Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:65, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 3 Main Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 3 Main Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:66, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 3 Stby Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 3 Stby Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:67, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 4 Main Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 4 Main Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:68, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 4 Stby Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Feed TK 4 Stby Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:69, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Inr Tk Xfr Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Inr Tk Xfr On Annunciator
(L:A380X_OVHD_FUEL_INRTK_XFR_PB_IS_AUTO, Bool) (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X L Inr Tk Aft Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X L Inr Tk Aft Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:74, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X L Inr Tk Fwd Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X L Inr Tk Fwd Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:73, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X L Mid Tk Aft Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X L Mid Tk Aft Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:72, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X L Mid Tk Fwd Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X L Mid Tk Fwd Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:71, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X L Outr Tk Pmp Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X L Outr Tk Pmp Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:70, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Mid Tk Xfr Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Mid Tk Xfr On Annunciator
(L:A380X_OVHD_FUEL_MIDTK_XFR_PB_IS_AUTO, Bool) (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Outr Tk Xfr Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Outr Tk Xfr Man Annunciator
(L:A380X_OVHD_FUEL_OUTRTK_XFR_PB_IS_AUTO, Bool) (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X R Inr Tk Aft Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X R Inr Tk Aft Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:79, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X R Inr Tk Fwd Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X R Inr Tk Fwd Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:78, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X R Mid Tk Aft Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X R Mid Tk Aft Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:77, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X R Mid Tk Fwd Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X R Mid Tk Fwd Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:76, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X R Outr Tk Pmp Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X R Outr Tk Pmp Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:75, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Trim Tk L Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Trim Tk L Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:80, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Trim Tk R Fuel Pump Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Trim Tk R Fuel Pump Off Annunciator
1 (>A:BUS LOOKUP INDEX, Number) (A:CIRCUIT CONNECTION ON:81, Bool) 0 == (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Trim Tk Xfr Fault Annunciator
(L:A32NX_OVHD_INTLT_ANN) 0 == 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink - FBW A380X Trim Tk Xfr On Annunciator
(L:A380X_OVHD_FUEL_TRIMTK_XFR_PB_IS_AUTO, Bool) (L:A32NX_OVHD_INTLT_ANN) 0 == or 1 and (L:A32NX_ELEC_AC_ESS_SHED_BUS_IS_POWERED, Bool) and (L:A32NX_OVHD_INTLT_ANN, number) 2 == if{ 0.1 } els{ 1 } * (A:CIRCUIT GENERAL PANEL ON, Bool) *by Andrew Spink
New to MobiFlight?
MobiFlight connects your switches, encoders and displays to the Fly By Wire A380X — every preset on this page is ready to use in it.
Download MobiFlight- Install MobiFlightand connect your board or device.
- Download the latest presetsExtras › HubHop › Download Latest Presets.
- Assign and flyPick a preset for each button, encoder or light.